symtab definition nvars=22
V'3 type=2 datasrc=1 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.design_inlet_temp
Physical Trough Power Block
Design inlet temperature
'C
n,exprlines=1
=${csp.dtr.solf.design_outlet_temp}
min=0 max=0
0
V'3 type=0 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.condenser_type
Physical Trough Power Block
Condenser type

n,exprlines=1
Evaporative,Air-cooled
min=0 max=0
0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.startup_time
Physical Trough Power Block
Power block startup time
hr
n,exprlines=0
min=0 max=0
1.0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.mc_balance
Physical Trough Power Block
Heat capacity of balance of plant
kWht/K-MWhe
n,exprlines=0
min=0 max=0
0.050000000000000003
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.max_turbine_over_design
Physical Trough Power Block
Max turbine over design operation

n,exprlines=0
min=0 max=0
1.1499999999999999
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.blowdown_frac
Physical Trough Power Block
Steam cycle blowdown fraction

n,exprlines=0
min=0 max=0
0.012999999999999999
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.min_turbine_frac
Physical Trough Power Block
Min turbine operation 

n,exprlines=0
min=0 max=0
0.25
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.ref_condenser_dt
Physical Trough Power Block
Ref. Condenser Water dT
'C
n,exprlines=0
min=0 max=0
10.0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.startup_temp
Physical Trough Power Block
Minimum required startup temp
'C
n,exprlines=0
min=0 max=0
350.0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.itd_design
Physical Trough Power Block
ITD at design point
'C
n,exprlines=0
min=0 max=0
16.0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.condenser_pressure_ratio
Physical Trough Power Block
Condenser pressure ratio

n,exprlines=0
min=0 max=0
1.0027999999999999
V'3 type=2 datasrc=1 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.design_outlet_temp
Physical Trough Power Block
Design outlet temperature
'C
n,exprlines=1
=${csp.dtr.solf.design_inlet_temp}
min=0 max=0
0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.ambient_design_temp
Physical Trough Power Block
Ambient temp at design
'C
n,exprlines=0
min=0 max=0
27.0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.standby_thermal_frac
Physical Trough Power Block
Fraction of thermal power needed for standby

n,exprlines=0
min=0 max=0
0.20000000000000001
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.startup_frac
Physical Trough Power Block
Fraction of thermal power needed for startup

n,exprlines=0
min=0 max=0
0.20000000000000001
V'3 type=2 datasrc=1 ---------------------------
0,0,0,0,0
csp.dtr.pwrb.nameplate
Physical Trough Power Block
Estimated net output at design (nameplate)
MWe
n,exprlines=1
=${csp.dtr.pwrb.design_gross_output}*${csp.dtr.pwrb.gross_net_conversion_factor}
min=0 max=0
0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.design_gross_output
Physical Trough Power Block
Design gross output
MWe
n,exprlines=0
min=0 max=0
110.0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.boiler_pressure
Physical Trough Power Block
Boiler operating pressure
bar
n,exprlines=0
min=0 max=0
100.0
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.rated_eff
Physical Trough Power Block
Rated cycle conversion efficiency

n,exprlines=0
min=0 max=0
0.37740000000000001
V'3 type=2 datasrc=0 ---------------------------
0,0,0,0,0
csp.dtr.pwrb.gross_net_conversion_factor
Physical Trough Power Block
Estimated gross to net conversion factor

n,exprlines=0
min=0 max=0
0.90000000000000002
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.boiler_lhv_eff
Physical Trough Power Block
Fossil backup boiler LHV efficiency

n,exprlines=0
min=0 max=0
0.90000000000000002
V'3 type=2 datasrc=0 ---------------------------
0,0,1,0,0
csp.dtr.pwrb.approach_temp
Physical Trough Power Block
Approach temperature
'C
n,exprlines=0
min=0 max=0
5.0